FTC LN Line Creation
Setup[edit | edit source]
- Fixture for the FTC end (fixed)
- Mount a horizontal 3/16 x 5 inch rod 20 inch above the edge of a flat work surface.
- Fix a stop collar 2 inch from the end of the rod.
- This end of the rod should protrude into the work volume.
- (the space above the work surface).
- This end of the rod should protrude into the work volume.
- Use a square to identify and mark a coordinate origin on the work surface directly beneath the center of the face of the stop collar that faces the work volume.
- Mark a coordinate axis on the work surface.
- Use the edge of a length of tape extending from the origin in the direction pointed by the rod.
- The axis should generally split the work surface in about half.
- Use one edge of the tape for the axis.
- Fixture for the LN Manifold end (free).
- Mount a second 3/16 x 5 inch rod vertically on a mobile stand
- So the rod can easily be positioned anywhere in the coordinate space.
- Locate the rod directly above a convenient edge of the stand.
- Fix a stop collar 1.5 inch from the top of the rod.
- Mark the point on the edge of the stand directly beneath the center of the rod.
Label and sleeve[edit | edit source]
- The bottom edge of the tape will be 1-5/16 in (1.3125) from the end of the tube
- The sleeve will be 1.5 in away from the end of the tube
- Start tape at opposite side of tube so that when fully wrapped the printed name for that tube is visible
- Place labels on the LN manifold frame to identify which FTC the tube goes to
- Make sure that the sleeve is stretched when it is on the tube so that it has a tight fit.