[[File:Adapter 0.75 Swagelok x 0.5 tube ORS exploded.png|alt=Adapter 0.75 Swagelok x 0.5 tube ORS exploded|thumb|Adapter 3/4 Swagelok x 1/2 tube ORS exploded]] | [[File:Adapter 0.75 Swagelok x 0.5 tube ORS exploded.png|alt=Adapter 0.75 Swagelok x 0.5 tube ORS exploded|thumb|Adapter 3/4 Swagelok x 1/2 tube ORS exploded]] | ||
# Preparation: | |||
#: Ensure that both the Swagelok fitting and the ORS tube are clean and free from any debris or contaminants. Use a clean cloth to wipe the surfaces if necessary. | |||
# Connecting the Adapter: | |||
#: Insert the Adapter 3/4 Swagelok x 1/2 tube into the 3/4 inch Swagelok fitting. Ensure that the adapter is fully seated and properly aligned. | |||
#: Align the ORS 3/4 with the 1/2 inch tube. The ORS 3/4 should fit snugly into the adapter. | |||
# Securing the Connection: | |||
#: Tighten the Swagelok fitting to secure the adapter. Use appropriate wrenches or pliers to achieve a firm connection, ensuring that the adapter does not shift or misalign during tightening. | |||
#: Verify that the ORS 3/4 is properly seated and that the O-Ring is in place. The O-Ring is designed to provide a leak-proof seal, so ensure it is not damaged or displaced. | |||
# Final Checks: | |||
#: After the connection is secured, perform a leak test if possible. This can be done by applying a suitable leak detection solution to the connection and checking for any signs of leakage. | |||
#: Ensure that all connections are firm and that there is no movement or play in the adapter. |
Latest revision as of 15:53, 26 July 2024
Instructions
- Preparation:
- Ensure that both the Swagelok fitting and the ORS tube are clean and free from any debris or contaminants. Use a clean cloth to wipe the surfaces if necessary.
- Connecting the Adapter:
- Insert the Adapter 3/4 Swagelok x 1/2 tube into the 3/4 inch Swagelok fitting. Ensure that the adapter is fully seated and properly aligned.
- Align the ORS 3/4 with the 1/2 inch tube. The ORS 3/4 should fit snugly into the adapter.
- Securing the Connection:
- Tighten the Swagelok fitting to secure the adapter. Use appropriate wrenches or pliers to achieve a firm connection, ensuring that the adapter does not shift or misalign during tightening.
- Verify that the ORS 3/4 is properly seated and that the O-Ring is in place. The O-Ring is designed to provide a leak-proof seal, so ensure it is not damaged or displaced.
- Final Checks:
- After the connection is secured, perform a leak test if possible. This can be done by applying a suitable leak detection solution to the connection and checking for any signs of leakage.
- Ensure that all connections are firm and that there is no movement or play in the adapter.